What is the minimum clearance around a hot water system?
Summary (TL;DR)
AS/NZS 3500.4 requires water heaters to be installed with adequate clearance for maintenance and replacement. For gas continuous flow units, AS/NZS 5601.1 mandates specific clearances from windows (usually 300mm-500mm depending on the flue) and internal corners.
Hot Water System Clearance Rules
When installing a new hot water system, you must satisfy both the plumbing standards (AS/NZS 3500.4), gas standards if applicable (AS/NZS 5601.1), and the manufacturer's specific installation instructions.
General Access (AS/NZS 3500.4)
The standard dictates that all water heaters must be placed so that:
- The rating plate and warning labels are visible
- The thermostat, heating element, and burner can be accessed and removed
- The PTR (Pressure Temperature Relief) valve can be safely operated and replaced
- The entire unit can be removed and replaced without causing structural damage to the building
Gas Continuous Flow Clearances (AS/NZS 5601.1)
For external gas continuous flow heaters, the flue terminal clearances are strict:
- From a window or door: Typically 300mm horizontally, but 500mm if the opening is above the flue.
- From an internal corner: Minimum 300mm.
- Below an eave or overhang: Minimum 300mm.
Indoor Storage Heaters (Safe Trays)
If an electric storage heater is installed indoors (e.g., in a cupboard), it must sit in a safe tray. There must be at least 20mm clearance between the water heater and the sides of the safe tray to allow water to flow freely to the tray waste.